Septic Systems in Madison County, Illinois

How much of Madison County the USDA rates as suitable for a septic drain field, what usually limits it, and the tank size Illinois requires.

Count every room that could be used as a bedroom. Most states size the tank by bedrooms, not by who lives there now.
Used only for the pumping estimate.

Minimum tank size

Illinois is selected. Choose your bedrooms and press Calculate.

Drain field suitability in Madison County

Most rated land in Madison County is very limited for a standard drain field: 91% of it. Expect a site evaluation to point many lots toward a larger field, pressure distribution or an engineered system.

  • 0% not limited
  • 8% somewhat limited
  • 85% very limited
  • 6% not rated (urban land, water, pits)

Share of the soil survey area's 458,319 acres, by the USDA rating “ENG – Septic Tank Absorption Fields”. Ratings assume a standard gravity trench system with no site changes, so “very limited” means a conventional field needs special design, not that septic is impossible.

What limits drain fields here

The most common limiting factors in Madison County, as a share of all its land. One soil can have several, so the figures overlap.

  • Slow-draining subsoil87% of the county

    Water moves too slowly through the soil 2 to 6 feet down, so effluent can back up or surface.

    Designers usually answer with a larger drain field, shallower trenches, pressure dosing or a mound.

  • High water table77% of the county

    The water table rises to within 4 to 6 feet of the surface for part of the year, leaving too little dry soil to treat effluent.

    Mounds, sand filters or treatment units that need less separation are common answers.

  • Ponding22% of the county

    Water stands on the surface for hours after rain, which saturates the drain field.

    Sites are often raised with a mound or moved to higher ground on the lot.

  • Flood-prone ground22% of the county

    The soil is on ground that floods, even if rarely, and a flooded drain field stops working.

    Systems are placed above flood level, with watertight tanks and backflow protection.

  • Steep slopes17% of the county

    Slopes over about 8% make it hard to keep trenches level and can let effluent seep out downhill.

    Trenches are laid along the contour, often with serial distribution or drip dispersal.

Main soils in Madison County

The soils and land types covering the most ground. Search your address in the USDA Web Soil Survey to see which one is on your lot.

Soil or land typeShare of county
Winfield7.7%
Menfro7.3%
Marine6.4%
Hickory5.8%
Virden3.4%
Wakeland3.4%
Herrick3.3%
Homen3.1%

Illinois tank size rules

Homes with up to 2 bedrooms need 750 gallons, 3 bedrooms 1,000, 4 bedrooms 1,250, 5 bedrooms 1,500 and 6 bedrooms 1,750. With a garbage grinder the figures rise to 1,125, 1,500, 2,000, 2,200 and 2,600 gallons.

BedroomsMinimum tank
1 BR750 gal
2 BR750 gal
3 BR1,000 gal
4 BR1,250 gal
5 BR1,500 gal
6 BR1,750 gal

Source: 77 Ill. Adm. Code 905, Appendix A, Illustration F.

All Illinois septic rules

Common questions

Can I put a conventional septic system in Madison County?

Often, but not everywhere. The USDA rates 9% of rated land here as not or only somewhat limited for a standard drain field and 91% as very limited. Only a site evaluation on your lot can say which you have.

What size septic tank do I need in Madison County?

Illinois's minimum is 1,000 gal for 3 bedrooms and 1,250 gal for 4. Your county can require more.

What is the most common septic problem with soil in Madison County?

Slow-draining subsoil, a limiting factor on about 87% of the county. Designers usually answer with a larger drain field, shallower trenches, pressure dosing or a mound.

Sources

  • https://sdmdataaccess.sc.egov.usda.gov/
  • https://websoilsurvey.nrcs.usda.gov/app/
  • https://www.nrcs.usda.gov/resources/data-and-reports/soil-survey-interpretations
  • https://www.epa.gov/septic/types-septic-systems
  • https://www.ilga.gov/commission/jcar/admincode/077/07700905zz9996afR.html
  • https://pubs.nmsu.edu/_m/M113/