Minimum tank size
Indiana is selected. Choose your bedrooms and press Calculate.
Drain field suitability in Henry County
Most rated land in Henry County is very limited for a standard drain field: 100% of it. Expect a site evaluation to point many lots toward a larger field, pressure distribution or an engineered system.
- 0% not limited
- 0% somewhat limited
- 98% very limited
- 2% not rated (urban land, water, pits)
Share of the soil survey area's 252,498 acres, by the USDA rating “ENG – Septic Tank Absorption Fields”. Ratings assume a standard gravity trench system with no site changes, so “very limited” means a conventional field needs special design, not that septic is impossible.
What limits drain fields here
The most common limiting factors in Henry County, as a share of all its land. One soil can have several, so the figures overlap.
High water table87% of the county
The water table rises to within 4 to 6 feet of the surface for part of the year, leaving too little dry soil to treat effluent.
Mounds, sand filters or treatment units that need less separation are common answers.
Slow-draining subsoil86% of the county
Water moves too slowly through the soil 2 to 6 feet down, so effluent can back up or surface.
Designers usually answer with a larger drain field, shallower trenches, pressure dosing or a mound.
Ponding28% of the county
Water stands on the surface for hours after rain, which saturates the drain field.
Sites are often raised with a mound or moved to higher ground on the lot.
Drains too fast21% of the county
Coarse soil at the bottom of the trench passes effluent through before it is treated, which risks groundwater.
Pretreatment units or a sand liner slow the flow and finish the treatment.
Steep slopes6% of the county
Slopes over about 8% make it hard to keep trenches level and can let effluent seep out downhill.
Trenches are laid along the contour, often with serial distribution or drip dispersal.
Main soils in Henry County
The soils and land types covering the most ground. Search your address in the USDA Web Soil Survey to see which one is on your lot.
| Soil or land type | Share of county |
|---|---|
| Crosby | 17.5% |
| Cyclone | 17.2% |
| Miamian | 11.2% |
| Losantville | 10.2% |
| Celina | 7.4% |
| Eldean | 7.4% |
| Miami | 4.8% |
| Westland | 3.9% |
Indiana tank size rules
Homes with up to 2 bedrooms need 750 gallons, 3 bedrooms 1,000, 4 bedrooms 1,250 and 5 bedrooms 1,500. Add 300 gallons for each bedroom over 5. A jetted tub that holds more than 125 gallons counts as an extra bedroom.
| Bedrooms | Minimum tank |
|---|---|
| 1 BR | 750 gal |
| 2 BR | 750 gal |
| 3 BR | 1,000 gal |
| 4 BR | 1,250 gal |
| 5 BR | 1,500 gal |
| 6 BR | 1,800 gal |
Source: 410 IAC 6-8.3-60(c), Table III.
Common questions
Can I put a conventional septic system in Henry County?
Often, but not everywhere. The USDA rates 0% of rated land here as not or only somewhat limited for a standard drain field and 100% as very limited. Only a site evaluation on your lot can say which you have.
What size septic tank do I need in Henry County?
Indiana's minimum is 1,000 gal for 3 bedrooms and 1,250 gal for 4. Your county can require more.
What is the most common septic problem with soil in Henry County?
High water table, a limiting factor on about 87% of the county. Mounds, sand filters or treatment units that need less separation are common answers.
More in Indiana
Sources
- https://sdmdataaccess.sc.egov.usda.gov/
- https://websoilsurvey.nrcs.usda.gov/app/
- https://www.nrcs.usda.gov/resources/data-and-reports/soil-survey-interpretations
- https://www.epa.gov/septic/types-septic-systems
- https://d1tvxue8o4w0fl.cloudfront.net/regulation/indiana-administrative-code/title-410-indiana-department-of-health/article-6-sanitary-engineering/rule-410-iac-6-83-residential-on-site-sewage-systems/section-410-iac-6-83-60-septic-tanks-general-requirements
- https://pubs.nmsu.edu/_m/M113/