Minimum tank size
Indiana is selected. Choose your bedrooms and press Calculate.
Drain field suitability in Rush County
Most rated land in Rush County is very limited for a standard drain field: 100% of it. Expect a site evaluation to point many lots toward a larger field, pressure distribution or an engineered system.
- 0% not limited
- 0% somewhat limited
- 100% very limited
- 0% not rated (urban land, water, pits)
Share of the soil survey area's 260,563 acres, by the USDA rating “ENG – Septic Tank Absorption Fields”. Ratings assume a standard gravity trench system with no site changes, so “very limited” means a conventional field needs special design, not that septic is impossible.
What limits drain fields here
The most common limiting factors in Rush County, as a share of all its land. One soil can have several, so the figures overlap.
Slow-draining subsoil99% of the county
Water moves too slowly through the soil 2 to 6 feet down, so effluent can back up or surface.
Designers usually answer with a larger drain field, shallower trenches, pressure dosing or a mound.
High water table91% of the county
The water table rises to within 4 to 6 feet of the surface for part of the year, leaving too little dry soil to treat effluent.
Mounds, sand filters or treatment units that need less separation are common answers.
Ponding31% of the county
Water stands on the surface for hours after rain, which saturates the drain field.
Sites are often raised with a mound or moved to higher ground on the lot.
Drains too fast17% of the county
Coarse soil at the bottom of the trench passes effluent through before it is treated, which risks groundwater.
Pretreatment units or a sand liner slow the flow and finish the treatment.
Flood-prone ground6% of the county
The soil is on ground that floods, even if rarely, and a flooded drain field stops working.
Systems are placed above flood level, with watertight tanks and backflow protection.
Main soils in Rush County
The soils and land types covering the most ground. Search your address in the USDA Web Soil Survey to see which one is on your lot.
| Soil or land type | Share of county |
|---|---|
| Crosby | 16.0% |
| Treaty | 12.0% |
| Miamian | 10.3% |
| Fincastle | 7.7% |
| Cyclone | 6.7% |
| Xenia | 6.1% |
| Miami | 6.1% |
| Westland | 3.6% |
Indiana tank size rules
Homes with up to 2 bedrooms need 750 gallons, 3 bedrooms 1,000, 4 bedrooms 1,250 and 5 bedrooms 1,500. Add 300 gallons for each bedroom over 5. A jetted tub that holds more than 125 gallons counts as an extra bedroom.
| Bedrooms | Minimum tank |
|---|---|
| 1 BR | 750 gal |
| 2 BR | 750 gal |
| 3 BR | 1,000 gal |
| 4 BR | 1,250 gal |
| 5 BR | 1,500 gal |
| 6 BR | 1,800 gal |
Source: 410 IAC 6-8.3-60(c), Table III.
Common questions
Can I put a conventional septic system in Rush County?
Often, but not everywhere. The USDA rates 0% of rated land here as not or only somewhat limited for a standard drain field and 100% as very limited. Only a site evaluation on your lot can say which you have.
What size septic tank do I need in Rush County?
Indiana's minimum is 1,000 gal for 3 bedrooms and 1,250 gal for 4. Your county can require more.
What is the most common septic problem with soil in Rush County?
Slow-draining subsoil, a limiting factor on about 99% of the county. Designers usually answer with a larger drain field, shallower trenches, pressure dosing or a mound.
More in Indiana
Sources
- https://sdmdataaccess.sc.egov.usda.gov/
- https://websoilsurvey.nrcs.usda.gov/app/
- https://www.nrcs.usda.gov/resources/data-and-reports/soil-survey-interpretations
- https://www.epa.gov/septic/types-septic-systems
- https://d1tvxue8o4w0fl.cloudfront.net/regulation/indiana-administrative-code/title-410-indiana-department-of-health/article-6-sanitary-engineering/rule-410-iac-6-83-residential-on-site-sewage-systems/section-410-iac-6-83-60-septic-tanks-general-requirements
- https://pubs.nmsu.edu/_m/M113/