Septic Tank Calculator

Home / By county / Minnesota

Septic Systems in Wabasha County, Minnesota

How much of Wabasha County the USDA rates as suitable for a septic drain field, what usually limits it, and the tank size Minnesota requires.

Count every room that could be used as a bedroom. Most states size the tank by bedrooms, not by who lives there now.
Used only for the pumping estimate.

Minimum tank size

Minnesota is selected. Choose your bedrooms and press Calculate.

Drain field suitability in Wabasha County

Soils in Wabasha County are mixed: 75% of rated land is very limited and 25% is not or only somewhat limited. The answer depends on the lot, so the soil test matters more than the county average.

  • 0% not limited
  • 24% somewhat limited
  • 71% very limited
  • 5% not rated (urban land, water, pits)

Share of the soil survey area's 351,899 acres, by the USDA rating “ENG – Septic Tank Absorption Fields”. Ratings assume a standard gravity trench system with no site changes, so “very limited” means a conventional field needs special design, not that septic is impossible.

What limits drain fields here

The most common limiting factors in Wabasha County, as a share of all its land. One soil can have several, so the figures overlap.

  • Slow-draining subsoil80% of the county

    Water moves too slowly through the soil 2 to 6 feet down, so effluent can back up or surface.

    Designers usually answer with a larger drain field, shallower trenches, pressure dosing or a mound.

  • Steep slopes48% of the county

    Slopes over about 8% make it hard to keep trenches level and can let effluent seep out downhill.

    Trenches are laid along the contour, often with serial distribution or drip dispersal.

  • High water table36% of the county

    The water table rises to within 4 to 6 feet of the surface for part of the year, leaving too little dry soil to treat effluent.

    Mounds, sand filters or treatment units that need less separation are common answers.

  • Drains too fast23% of the county

    Coarse soil at the bottom of the trench passes effluent through before it is treated, which risks groundwater.

    Pretreatment units or a sand liner slow the flow and finish the treatment.

  • Flood-prone ground14% of the county

    The soil is on ground that floods, even if rarely, and a flooded drain field stops working.

    Systems are placed above flood level, with watertight tanks and backflow protection.

Main soils in Wabasha County

The soils and land types covering the most ground. Search your address in the USDA Web Soil Survey to see which one is on your lot.

Soil or land typeShare of county
Hersey16.4%
Mt. Carroll14.0%
Downs12.7%
Frontenac5.9%
Dubuque5.2%
Water4.6%
Lacrescent3.3%
Chaseburg3.0%

Minnesota tank size rules

Homes with up to 3 bedrooms need 1,000 gallons, 4 or 5 bedrooms 1,500, 6 or 7 bedrooms 2,000 and 8 or 9 bedrooms 2,500. Above 9 bedrooms, add 250 gallons per bedroom.

BedroomsMinimum tank
1 BR1,000 gal
2 BR1,000 gal
3 BR1,000 gal
4 BR1,500 gal
5 BR1,500 gal
6 BR2,000 gal

Source: Minn. R. 7080.1930 Table V.

All Minnesota septic rules

Common questions

Can I put a conventional septic system in Wabasha County?

Often, but not everywhere. The USDA rates 25% of rated land here as not or only somewhat limited for a standard drain field and 75% as very limited. Only a site evaluation on your lot can say which you have.

What size septic tank do I need in Wabasha County?

Minnesota's minimum is 1,000 gal for 3 bedrooms and 1,500 gal for 4. Your county can require more.

What is the most common septic problem with soil in Wabasha County?

Slow-draining subsoil, a limiting factor on about 80% of the county. Designers usually answer with a larger drain field, shallower trenches, pressure dosing or a mound.

Sources

  • https://sdmdataaccess.sc.egov.usda.gov/
  • https://websoilsurvey.nrcs.usda.gov/app/
  • https://www.nrcs.usda.gov/resources/data-and-reports/soil-survey-interpretations
  • https://www.epa.gov/septic/types-septic-systems
  • https://regulations.justia.com/states/minnesota/agency-167/chapter-7080/part-7080-1930
  • https://pubs.nmsu.edu/_m/M113/