Home / By county / Mississippi
Septic Systems in Covington County, Mississippi
How much of Covington County the USDA rates as suitable for a septic drain field, what usually limits it, and the tank size Mississippi requires.
Minimum tank size
Mississippi is selected. Choose your bedrooms and press Calculate.
Drain field suitability in Covington County
Most rated land in Covington County is very limited for a standard drain field: 81% of it. Expect a site evaluation to point many lots toward a larger field, pressure distribution or an engineered system.
- 1% not limited
- 17% somewhat limited
- 80% very limited
- 1% not rated (urban land, water, pits)
Share of the soil survey area's 256,040 acres, by the USDA rating “ENG – Septic Tank Absorption Fields”. Ratings assume a standard gravity trench system with no site changes, so “very limited” means a conventional field needs special design, not that septic is impossible.
What limits drain fields here
The most common limiting factors in Covington County, as a share of all its land. One soil can have several, so the figures overlap.
Slow-draining subsoil82% of the county
Water moves too slowly through the soil 2 to 6 feet down, so effluent can back up or surface.
Designers usually answer with a larger drain field, shallower trenches, pressure dosing or a mound.
High water table45% of the county
The water table rises to within 4 to 6 feet of the surface for part of the year, leaving too little dry soil to treat effluent.
Mounds, sand filters or treatment units that need less separation are common answers.
Drains too fast29% of the county
Coarse soil at the bottom of the trench passes effluent through before it is treated, which risks groundwater.
Pretreatment units or a sand liner slow the flow and finish the treatment.
Steep slopes25% of the county
Slopes over about 8% make it hard to keep trenches level and can let effluent seep out downhill.
Trenches are laid along the contour, often with serial distribution or drip dispersal.
Flood-prone ground21% of the county
The soil is on ground that floods, even if rarely, and a flooded drain field stops working.
Systems are placed above flood level, with watertight tanks and backflow protection.
Main soils in Covington County
The soils and land types covering the most ground. Search your address in the USDA Web Soil Survey to see which one is on your lot.
| Soil or land type | Share of county |
|---|---|
| Smithdale | 18.5% |
| Ruston | 16.7% |
| Ora | 12.4% |
| Savannah | 7.5% |
| Jena | 5.3% |
| Oaklimeter | 4.0% |
| Rosebloom | 3.3% |
| Trebloc | 3.0% |
Mississippi tank size rules
With an effluent filter or baffle, homes with up to 2 bedrooms need 750 gallons, 3 bedrooms 900, 4 bedrooms 1,000, 5 bedrooms 1,250 and 6 bedrooms 1,500. Without one the sizes are larger, and more than 2 occupants per bedroom adds 130 gallons per person.
| Bedrooms | Minimum tank |
|---|---|
| 1 BR | 750 gal |
| 2 BR | 750 gal |
| 3 BR | 900 gal |
| 4 BR | 1,000 gal |
| 5 BR | 1,250 gal |
| 6 BR | 1,500 gal |
Source: 15 Miss. Code R. 18-77-5.1.9.
Common questions
Can I put a conventional septic system in Covington County?
Often, but not everywhere. The USDA rates 19% of rated land here as not or only somewhat limited for a standard drain field and 81% as very limited. Only a site evaluation on your lot can say which you have.
What size septic tank do I need in Covington County?
Mississippi's minimum is 900 gal for 3 bedrooms and 1,000 gal for 4. Your county can require more.
What is the most common septic problem with soil in Covington County?
Slow-draining subsoil, a limiting factor on about 82% of the county. Designers usually answer with a larger drain field, shallower trenches, pressure dosing or a mound.
More in Mississippi
Sources
- https://sdmdataaccess.sc.egov.usda.gov/
- https://websoilsurvey.nrcs.usda.gov/app/
- https://www.nrcs.usda.gov/resources/data-and-reports/soil-survey-interpretations
- https://www.epa.gov/septic/types-septic-systems
- https://www.law.cornell.edu/regulations/mississippi/15-Miss-Code-R-SS-18-77-5-1-9
- https://pubs.nmsu.edu/_m/M113/