Minimum tank size
Missouri is selected. Choose your bedrooms and press Calculate.
Drain field suitability in Gasconade County
Most rated land in Gasconade County is very limited for a standard drain field: 100% of it. Expect a site evaluation to point many lots toward a larger field, pressure distribution or an engineered system.
- 0% not limited
- 0% somewhat limited
- 98% very limited
- 2% not rated (urban land, water, pits)
Share of the soil survey area's 335,499 acres, by the USDA rating “ENG – Septic Tank Absorption Fields”. Ratings assume a standard gravity trench system with no site changes, so “very limited” means a conventional field needs special design, not that septic is impossible.
What limits drain fields here
The most common limiting factors in Gasconade County, as a share of all its land. One soil can have several, so the figures overlap.
Slow-draining subsoil91% of the county
Water moves too slowly through the soil 2 to 6 feet down, so effluent can back up or surface.
Designers usually answer with a larger drain field, shallower trenches, pressure dosing or a mound.
High water table78% of the county
The water table rises to within 4 to 6 feet of the surface for part of the year, leaving too little dry soil to treat effluent.
Mounds, sand filters or treatment units that need less separation are common answers.
Steep slopes53% of the county
Slopes over about 8% make it hard to keep trenches level and can let effluent seep out downhill.
Trenches are laid along the contour, often with serial distribution or drip dispersal.
Shallow bedrock40% of the county
Rock lies within about 3 to 6 feet of the surface, so there is little soil to filter effluent before it reaches the rock.
At-grade systems, mounds or drip dispersal add soil depth above the rock.
Flood-prone ground16% of the county
The soil is on ground that floods, even if rarely, and a flooded drain field stops working.
Systems are placed above flood level, with watertight tanks and backflow protection.
Main soils in Gasconade County
The soils and land types covering the most ground. Search your address in the USDA Web Soil Survey to see which one is on your lot.
| Soil or land type | Share of county |
|---|---|
| Beemont | 23.0% |
| Union | 19.2% |
| Wrengart | 7.4% |
| Gatewood | 7.0% |
| Gladden | 4.6% |
| Menfro | 3.4% |
| Coulstone | 3.0% |
| Hartville | 3.0% |
Missouri tank size rules
Homes with up to 3 bedrooms need 1,000 gallons, 4 bedrooms 1,250 and 5 bedrooms 1,500. Homes with 6 or more bedrooms are sized individually. The bedroom count is the one an appraiser would give.
| Bedrooms | Minimum tank |
|---|---|
| 1 BR | 1,000 gal |
| 2 BR | 1,000 gal |
| 3 BR | 1,000 gal |
| 4 BR | 1,250 gal |
| 5 BR | 1,500 gal |
| 6 BR | Set locally |
Source: 19 CSR 20-3.060(4)(B)16, Table 4.
Common questions
Can I put a conventional septic system in Gasconade County?
Often, but not everywhere. The USDA rates 0% of rated land here as not or only somewhat limited for a standard drain field and 100% as very limited. Only a site evaluation on your lot can say which you have.
What size septic tank do I need in Gasconade County?
Missouri's minimum is 1,000 gal for 3 bedrooms and 1,250 gal for 4. Your county can require more.
What is the most common septic problem with soil in Gasconade County?
Slow-draining subsoil, a limiting factor on about 91% of the county. Designers usually answer with a larger drain field, shallower trenches, pressure dosing or a mound.
More in Missouri
Sources
- https://sdmdataaccess.sc.egov.usda.gov/
- https://websoilsurvey.nrcs.usda.gov/app/
- https://www.nrcs.usda.gov/resources/data-and-reports/soil-survey-interpretations
- https://www.epa.gov/septic/types-septic-systems
- https://health.mo.gov/living/environment/onsite/pdf/onsite_ref_book.pdf
- https://pubs.nmsu.edu/_m/M113/