Septic Tank Calculator

Home / By county / Nebraska

Septic Systems in Box Butte County, Nebraska

How much of Box Butte County the USDA rates as suitable for a septic drain field, what usually limits it, and the tank size Nebraska requires.

Count every room that could be used as a bedroom. Most states size the tank by bedrooms, not by who lives there now.
Used only for the pumping estimate.

Minimum tank size

Nebraska is selected. Choose your bedrooms and press Calculate.

Drain field suitability in Box Butte County

About 56% of rated land in Box Butte County is not limited or only somewhat limited, so a conventional trench system is often workable once a site evaluation confirms it.

  • 7% not limited
  • 49% somewhat limited
  • 44% very limited
  • 0% not rated (urban land, water, pits)

Share of the soil survey area's 689,573 acres, by the USDA rating “ENG – Septic Tank Absorption Fields”. Ratings assume a standard gravity trench system with no site changes, so “very limited” means a conventional field needs special design, not that septic is impossible.

What limits drain fields here

The most common limiting factors in Box Butte County, as a share of all its land. One soil can have several, so the figures overlap.

  • Slow-draining subsoil53% of the county

    Water moves too slowly through the soil 2 to 6 feet down, so effluent can back up or surface.

    Designers usually answer with a larger drain field, shallower trenches, pressure dosing or a mound.

  • Shallow bedrock42% of the county

    Rock lies within about 3 to 6 feet of the surface, so there is little soil to filter effluent before it reaches the rock.

    At-grade systems, mounds or drip dispersal add soil depth above the rock.

  • Drains too fast18% of the county

    Coarse soil at the bottom of the trench passes effluent through before it is treated, which risks groundwater.

    Pretreatment units or a sand liner slow the flow and finish the treatment.

  • Poor filtering layer16% of the county

    Very permeable material 2 to 5 feet down filters effluent poorly.

    Pretreatment or added fill gives the effluent more treatment before it reaches that layer.

  • Steep slopes13% of the county

    Slopes over about 8% make it hard to keep trenches level and can let effluent seep out downhill.

    Trenches are laid along the contour, often with serial distribution or drip dispersal.

Main soils in Box Butte County

The soils and land types covering the most ground. Search your address in the USDA Web Soil Survey to see which one is on your lot.

Soil or land typeShare of county
Alliance14.3%
Keith7.5%
Creighton7.4%
Rosebud6.9%
Busher6.8%
Valentine5.7%
Valent5.1%
Duroc4.0%

Nebraska tank size rules

Nebraska sizes the tank from design flow, 100 gallons a day plus 100 per bedroom: up to 400 gallons a day needs 1,000 gallons, 500 needs 1,250, 600 needs 1,500 and 700 needs 1,750. A garbage grinder or a large tub raises the size.

BedroomsMinimum tank
1 BR1,000 gal
2 BR1,000 gal
3 BR1,000 gal
4 BR1,250 gal
5 BR1,500 gal
6 BR1,750 gal

Source: Title 124, Table 10.1.

All Nebraska septic rules

Common questions

Can I put a conventional septic system in Box Butte County?

Often, but not everywhere. The USDA rates 56% of rated land here as not or only somewhat limited for a standard drain field and 44% as very limited. Only a site evaluation on your lot can say which you have.

What size septic tank do I need in Box Butte County?

Nebraska's minimum is 1,000 gal for 3 bedrooms and 1,250 gal for 4. Your county can require more.

What is the most common septic problem with soil in Box Butte County?

Slow-draining subsoil, a limiting factor on about 53% of the county. Designers usually answer with a larger drain field, shallower trenches, pressure dosing or a mound.

Sources

  • https://sdmdataaccess.sc.egov.usda.gov/
  • https://websoilsurvey.nrcs.usda.gov/app/
  • https://www.nrcs.usda.gov/resources/data-and-reports/soil-survey-interpretations
  • https://www.epa.gov/septic/types-septic-systems
  • https://dee.nebraska.gov/sites/default/files/publications/12-036%20Septic%20and%20Holding%20Tank%20Fact%20Sheet.pdf
  • https://pubs.nmsu.edu/_m/M113/