Home / By county / New Jersey
Septic Systems in Passaic County, New Jersey
How much of Passaic County the USDA rates as suitable for a septic drain field, what usually limits it, and the tank size New Jersey requires.
Minimum tank size
New Jersey is selected. Choose your bedrooms and press Calculate.
Drain field suitability in Passaic County
Most rated land in Passaic County is very limited for a standard drain field: 91% of it. Expect a site evaluation to point many lots toward a larger field, pressure distribution or an engineered system.
- 6% not limited
- 2% somewhat limited
- 83% very limited
- 8% not rated (urban land, water, pits)
Share of the soil survey area's 125,998 acres, by the USDA rating “ENG – Septic Tank Absorption Fields”. Ratings assume a standard gravity trench system with no site changes, so “very limited” means a conventional field needs special design, not that septic is impossible.
What limits drain fields here
The most common limiting factors in Passaic County, as a share of all its land. One soil can have several, so the figures overlap.
High water table51% of the county
The water table rises to within 4 to 6 feet of the surface for part of the year, leaving too little dry soil to treat effluent.
Mounds, sand filters or treatment units that need less separation are common answers.
Steep slopes50% of the county
Slopes over about 8% make it hard to keep trenches level and can let effluent seep out downhill.
Trenches are laid along the contour, often with serial distribution or drip dispersal.
Drains too fast41% of the county
Coarse soil at the bottom of the trench passes effluent through before it is treated, which risks groundwater.
Pretreatment units or a sand liner slow the flow and finish the treatment.
Slow-draining subsoil17% of the county
Water moves too slowly through the soil 2 to 6 feet down, so effluent can back up or surface.
Designers usually answer with a larger drain field, shallower trenches, pressure dosing or a mound.
Shallow bedrock16% of the county
Rock lies within about 3 to 6 feet of the surface, so there is little soil to filter effluent before it reaches the rock.
At-grade systems, mounds or drip dispersal add soil depth above the rock.
Main soils in Passaic County
The soils and land types covering the most ground. Search your address in the USDA Web Soil Survey to see which one is on your lot.
| Soil or land type | Share of county |
|---|---|
| Rockaway | 20.1% |
| Urban land | 14.1% |
| Rock outcrop | 11.9% |
| Swartswood | 7.5% |
| Water | 6.3% |
| Boonton | 5.5% |
| Riverhead | 4.5% |
| Hibernia | 3.8% |
New Jersey tank size rules
New Jersey requires 250 gallons per bedroom and never less than 1,000 gallons. An expansion attic counts as a bedroom. A garbage grinder or a sewage ejector pump adds 50% and requires a multi-compartment tank.
| Bedrooms | Minimum tank |
|---|---|
| 1 BR | 1,000 gal |
| 2 BR | 1,000 gal |
| 3 BR | 1,000 gal |
| 4 BR | 1,000 gal |
| 5 BR | 1,250 gal |
| 6 BR | 1,500 gal |
Source: N.J.A.C. 7:9A-8.2(b)1.
Common questions
Can I put a conventional septic system in Passaic County?
Often, but not everywhere. The USDA rates 9% of rated land here as not or only somewhat limited for a standard drain field and 91% as very limited. Only a site evaluation on your lot can say which you have.
What size septic tank do I need in Passaic County?
New Jersey's minimum is 1,000 gal for 3 bedrooms and 1,000 gal for 4. Your county can require more.
What is the most common septic problem with soil in Passaic County?
High water table, a limiting factor on about 51% of the county. Mounds, sand filters or treatment units that need less separation are common answers.
More in New Jersey
Sources
- https://sdmdataaccess.sc.egov.usda.gov/
- https://websoilsurvey.nrcs.usda.gov/app/
- https://www.nrcs.usda.gov/resources/data-and-reports/soil-survey-interpretations
- https://www.epa.gov/septic/types-septic-systems
- https://trellis.law/state-rules/nj/administrative-code/title-7-environmental-protection/chapter-9a-standards-for-individual-subsurface-sewage-disposal-systems/subchapter-8-pretreatment-components/section-79a-82-septic-tanks