Septic Tank Calculator

Home / By county / New York

Septic Systems in Yates County, New York

How much of Yates County the USDA rates as suitable for a septic drain field, what usually limits it, and the tank size New York requires.

Count every room that could be used as a bedroom. Most states size the tank by bedrooms, not by who lives there now.
Used only for the pumping estimate.

Minimum tank size

New York is selected. Choose your bedrooms and press Calculate.

Drain field suitability in Yates County

Most rated land in Yates County is very limited for a standard drain field: 87% of it. Expect a site evaluation to point many lots toward a larger field, pressure distribution or an engineered system.

  • 0% not limited
  • 12% somewhat limited
  • 79% very limited
  • 9% not rated (urban land, water, pits)

Share of the soil survey area's 236,276 acres, by the USDA rating “ENG – Septic Tank Absorption Fields”. Ratings assume a standard gravity trench system with no site changes, so “very limited” means a conventional field needs special design, not that septic is impossible.

What limits drain fields here

The most common limiting factors in Yates County, as a share of all its land. One soil can have several, so the figures overlap.

  • High water table59% of the county

    The water table rises to within 4 to 6 feet of the surface for part of the year, leaving too little dry soil to treat effluent.

    Mounds, sand filters or treatment units that need less separation are common answers.

  • Slow-draining subsoil52% of the county

    Water moves too slowly through the soil 2 to 6 feet down, so effluent can back up or surface.

    Designers usually answer with a larger drain field, shallower trenches, pressure dosing or a mound.

  • Steep slopes31% of the county

    Slopes over about 8% make it hard to keep trenches level and can let effluent seep out downhill.

    Trenches are laid along the contour, often with serial distribution or drip dispersal.

  • Drains too fast17% of the county

    Coarse soil at the bottom of the trench passes effluent through before it is treated, which risks groundwater.

    Pretreatment units or a sand liner slow the flow and finish the treatment.

  • Shallow bedrock12% of the county

    Rock lies within about 3 to 6 feet of the surface, so there is little soil to filter effluent before it reaches the rock.

    At-grade systems, mounds or drip dispersal add soil depth above the rock.

Main soils in Yates County

The soils and land types covering the most ground. Search your address in the USDA Web Soil Survey to see which one is on your lot.

Soil or land typeShare of county
Water8.5%
Honeoye7.3%
Lima5.8%
Mardin5.0%
Valois4.9%
Langford4.6%
Lansing4.0%
Erie3.6%

New York tank size rules

Homes with up to 3 bedrooms need 1,000 gallons, 4 bedrooms 1,250, 5 bedrooms 1,500 and 6 bedrooms 1,750. Add 250 gallons for each bedroom beyond 6. An expansion attic counts as a bedroom.

BedroomsMinimum tank
1 BR1,000 gal
2 BR1,000 gal
3 BR1,000 gal
4 BR1,250 gal
5 BR1,500 gal
6 BR1,750 gal

Source: 10 NYCRR Appendix 75-A.6, Table 3.

All New York septic rules

Common questions

Can I put a conventional septic system in Yates County?

Often, but not everywhere. The USDA rates 13% of rated land here as not or only somewhat limited for a standard drain field and 87% as very limited. Only a site evaluation on your lot can say which you have.

What size septic tank do I need in Yates County?

New York's minimum is 1,000 gal for 3 bedrooms and 1,250 gal for 4. Your county can require more.

What is the most common septic problem with soil in Yates County?

High water table, a limiting factor on about 59% of the county. Mounds, sand filters or treatment units that need less separation are common answers.

Sources

  • https://sdmdataaccess.sc.egov.usda.gov/
  • https://websoilsurvey.nrcs.usda.gov/app/
  • https://www.nrcs.usda.gov/resources/data-and-reports/soil-survey-interpretations
  • https://www.epa.gov/septic/types-septic-systems
  • https://regs.health.ny.gov/node/45071
  • https://pubs.nmsu.edu/_m/M113/