Home / By county / North Carolina
Septic Systems in Pitt County, North Carolina
How much of Pitt County the USDA rates as suitable for a septic drain field, what usually limits it, and the tank size North Carolina requires.
Minimum tank size
North Carolina is selected. Choose your bedrooms and press Calculate.
Drain field suitability in Pitt County
Most rated land in Pitt County is very limited for a standard drain field: 88% of it. Expect a site evaluation to point many lots toward a larger field, pressure distribution or an engineered system.
- 0% not limited
- 12% somewhat limited
- 87% very limited
- 1% not rated (urban land, water, pits)
Share of the soil survey area's 385,199 acres, by the USDA rating “ENG – Septic Tank Absorption Fields”. Ratings assume a standard gravity trench system with no site changes, so “very limited” means a conventional field needs special design, not that septic is impossible.
What limits drain fields here
The most common limiting factors in Pitt County, as a share of all its land. One soil can have several, so the figures overlap.
High water table89% of the county
The water table rises to within 4 to 6 feet of the surface for part of the year, leaving too little dry soil to treat effluent.
Mounds, sand filters or treatment units that need less separation are common answers.
Slow-draining subsoil81% of the county
Water moves too slowly through the soil 2 to 6 feet down, so effluent can back up or surface.
Designers usually answer with a larger drain field, shallower trenches, pressure dosing or a mound.
Flood-prone ground26% of the county
The soil is on ground that floods, even if rarely, and a flooded drain field stops working.
Systems are placed above flood level, with watertight tanks and backflow protection.
Drains too fast25% of the county
Coarse soil at the bottom of the trench passes effluent through before it is treated, which risks groundwater.
Pretreatment units or a sand liner slow the flow and finish the treatment.
Ponding5% of the county
Water stands on the surface for hours after rain, which saturates the drain field.
Sites are often raised with a mound or moved to higher ground on the lot.
Main soils in Pitt County
The soils and land types covering the most ground. Search your address in the USDA Web Soil Survey to see which one is on your lot.
| Soil or land type | Share of county |
|---|---|
| Rains | 8.2% |
| Exum | 7.7% |
| Coxville | 7.1% |
| Lynchburg | 6.3% |
| Wagram | 6.0% |
| Bladen | 5.2% |
| Lenoir | 4.4% |
| Norfolk | 4.4% |
North Carolina tank size rules
Homes with up to 4 bedrooms need 1,000 gallons and 5 bedrooms need 1,250. Larger homes are sized from design flow at 120 gallons a day per bedroom. The size doubles when a garbage grinder or a lift pump comes before the tank.
| Bedrooms | Minimum tank |
|---|---|
| 1 BR | 1,000 gal |
| 2 BR | 1,000 gal |
| 3 BR | 1,000 gal |
| 4 BR | 1,000 gal |
| 5 BR | 1,250 gal |
| 6 BR | 1,343 gal |
Source: 15A NCAC 18E .0801.
Common questions
Can I put a conventional septic system in Pitt County?
Often, but not everywhere. The USDA rates 12% of rated land here as not or only somewhat limited for a standard drain field and 88% as very limited. Only a site evaluation on your lot can say which you have.
What size septic tank do I need in Pitt County?
North Carolina's minimum is 1,000 gal for 3 bedrooms and 1,000 gal for 4. Your county can require more.
What is the most common septic problem with soil in Pitt County?
High water table, a limiting factor on about 89% of the county. Mounds, sand filters or treatment units that need less separation are common answers.
More in North Carolina
Sources
- https://sdmdataaccess.sc.egov.usda.gov/
- https://websoilsurvey.nrcs.usda.gov/app/
- https://www.nrcs.usda.gov/resources/data-and-reports/soil-survey-interpretations
- https://www.epa.gov/septic/types-septic-systems
- https://www.owpnc.com/18e-rules-nc/0801-septic-tank-capacity-requirements
- https://pubs.nmsu.edu/_m/M113/