Minimum tank size
Texas is selected. Choose your bedrooms and press Calculate.
Drain field suitability in Nolan County
Most rated land in Nolan County is very limited for a standard drain field: 89% of it. Expect a site evaluation to point many lots toward a larger field, pressure distribution or an engineered system.
- 0% not limited
- 10% somewhat limited
- 80% very limited
- 9% not rated (urban land, water, pits)
Share of the soil survey area's 586,290 acres, by the USDA rating “ENG – Septic Tank Absorption Fields”. Ratings assume a standard gravity trench system with no site changes, so “very limited” means a conventional field needs special design, not that septic is impossible.
What limits drain fields here
The most common limiting factors in Nolan County, as a share of all its land. One soil can have several, so the figures overlap.
Shallow bedrock52% of the county
Rock lies within about 3 to 6 feet of the surface, so there is little soil to filter effluent before it reaches the rock.
At-grade systems, mounds or drip dispersal add soil depth above the rock.
Slow-draining subsoil41% of the county
Water moves too slowly through the soil 2 to 6 feet down, so effluent can back up or surface.
Designers usually answer with a larger drain field, shallower trenches, pressure dosing or a mound.
Hardpan or caliche11% of the county
A cemented layer within about 3 to 6 feet blocks downward drainage.
Trenches may be dug through the pan, or a mound placed above it.
Steep slopes11% of the county
Slopes over about 8% make it hard to keep trenches level and can let effluent seep out downhill.
Trenches are laid along the contour, often with serial distribution or drip dispersal.
Flood-prone ground6% of the county
The soil is on ground that floods, even if rarely, and a flooded drain field stops working.
Systems are placed above flood level, with watertight tanks and backflow protection.
Main soils in Nolan County
The soils and land types covering the most ground. Search your address in the USDA Web Soil Survey to see which one is on your lot.
| Soil or land type | Share of county |
|---|---|
| Oplin | 25.5% |
| Pyron | 9.4% |
| Dermott | 3.9% |
| Shep | 3.7% |
| Gageby | 3.4% |
| Quinlan | 3.3% |
| Woodward | 3.2% |
| Sagerton | 3.2% |
Texas tank size rules
Texas sets a daily design flow from bedrooms and living area (Table III), then sizes the tank from that flow (Table II): up to 250 gallons a day needs 750 gallons, 251 to 350 needs 1,000, 351 to 500 needs 1,250, and 501 to 1,000 needs 2.5 times the flow. The figures here assume the living area fits the bedroom count, for example under 2,500 sq ft for 3 bedrooms. Water-saving fixtures throughout lower the design flow.
| Bedrooms | Minimum tank |
|---|---|
| 1 BR | 750 gal |
| 2 BR | 750 gal |
| 3 BR | 1,000 gal |
| 4 BR | 1,250 gal |
| 5 BR | 1,250 gal |
| 6 BR | 1,313 gal |
Source: 30 TAC 285.91, Tables II and III.
Common questions
Can I put a conventional septic system in Nolan County?
Often, but not everywhere. The USDA rates 11% of rated land here as not or only somewhat limited for a standard drain field and 89% as very limited. Only a site evaluation on your lot can say which you have.
What size septic tank do I need in Nolan County?
Texas's minimum is 1,000 gal for 3 bedrooms and 1,250 gal for 4. Your county can require more.
What is the most common septic problem with soil in Nolan County?
Shallow bedrock, a limiting factor on about 52% of the county. At-grade systems, mounds or drip dispersal add soil depth above the rock.
More in Texas
Sources
- https://sdmdataaccess.sc.egov.usda.gov/
- https://websoilsurvey.nrcs.usda.gov/app/
- https://www.nrcs.usda.gov/resources/data-and-reports/soil-survey-interpretations
- https://www.epa.gov/septic/types-septic-systems
- https://regulations.justia.com/resources/v2025050500/tx/admin/2025/tx30_285_91_200804579_4.pdf
- https://pubs.nmsu.edu/_m/M113/