Minimum tank size
Texas is selected. Choose your bedrooms and press Calculate.
Drain field suitability in Terry County
About 83% of rated land in Terry County is not limited or only somewhat limited, so a conventional trench system is often workable once a site evaluation confirms it.
- 1% not limited
- 81% somewhat limited
- 17% very limited
- 1% not rated (urban land, water, pits)
Share of the soil survey area's 570,443 acres, by the USDA rating “ENG – Septic Tank Absorption Fields”. Ratings assume a standard gravity trench system with no site changes, so “very limited” means a conventional field needs special design, not that septic is impossible.
What limits drain fields here
The most common limiting factors in Terry County, as a share of all its land. One soil can have several, so the figures overlap.
Slow-draining subsoil96% of the county
Water moves too slowly through the soil 2 to 6 feet down, so effluent can back up or surface.
Designers usually answer with a larger drain field, shallower trenches, pressure dosing or a mound.
Drains too fast8% of the county
Coarse soil at the bottom of the trench passes effluent through before it is treated, which risks groundwater.
Pretreatment units or a sand liner slow the flow and finish the treatment.
Hardpan or caliche6% of the county
A cemented layer within about 3 to 6 feet blocks downward drainage.
Trenches may be dug through the pan, or a mound placed above it.
Flood-prone ground2% of the county
The soil is on ground that floods, even if rarely, and a flooded drain field stops working.
Systems are placed above flood level, with watertight tanks and backflow protection.
High water table1% of the county
The water table rises to within 4 to 6 feet of the surface for part of the year, leaving too little dry soil to treat effluent.
Mounds, sand filters or treatment units that need less separation are common answers.
Main soils in Terry County
The soils and land types covering the most ground. Search your address in the USDA Web Soil Survey to see which one is on your lot.
| Soil or land type | Share of county |
|---|---|
| Amarillo | 38.8% |
| Patricia | 23.0% |
| Midessa | 6.5% |
| Tokio | 3.6% |
| Arvana | 2.8% |
| Posey | 2.6% |
| Pep | 1.4% |
| Brownfield | 1.3% |
Texas tank size rules
Texas sets a daily design flow from bedrooms and living area (Table III), then sizes the tank from that flow (Table II): up to 250 gallons a day needs 750 gallons, 251 to 350 needs 1,000, 351 to 500 needs 1,250, and 501 to 1,000 needs 2.5 times the flow. The figures here assume the living area fits the bedroom count, for example under 2,500 sq ft for 3 bedrooms. Water-saving fixtures throughout lower the design flow.
| Bedrooms | Minimum tank |
|---|---|
| 1 BR | 750 gal |
| 2 BR | 750 gal |
| 3 BR | 1,000 gal |
| 4 BR | 1,250 gal |
| 5 BR | 1,250 gal |
| 6 BR | 1,313 gal |
Source: 30 TAC 285.91, Tables II and III.
Common questions
Can I put a conventional septic system in Terry County?
Often, but not everywhere. The USDA rates 83% of rated land here as not or only somewhat limited for a standard drain field and 17% as very limited. Only a site evaluation on your lot can say which you have.
What size septic tank do I need in Terry County?
Texas's minimum is 1,000 gal for 3 bedrooms and 1,250 gal for 4. Your county can require more.
What is the most common septic problem with soil in Terry County?
Slow-draining subsoil, a limiting factor on about 96% of the county. Designers usually answer with a larger drain field, shallower trenches, pressure dosing or a mound.
More in Texas
Sources
- https://sdmdataaccess.sc.egov.usda.gov/
- https://websoilsurvey.nrcs.usda.gov/app/
- https://www.nrcs.usda.gov/resources/data-and-reports/soil-survey-interpretations
- https://www.epa.gov/septic/types-septic-systems
- https://regulations.justia.com/resources/v2025050500/tx/admin/2025/tx30_285_91_200804579_4.pdf
- https://pubs.nmsu.edu/_m/M113/