Minimum tank size
Wyoming is selected. Choose your bedrooms and press Calculate.
Drain field suitability in Fremont County, Lander Area
Most rated land in Fremont County, Lander Area is very limited for a standard drain field: 89% of it. Expect a site evaluation to point many lots toward a larger field, pressure distribution or an engineered system.
- 0% not limited
- 8% somewhat limited
- 68% very limited
- 24% not rated (urban land, water, pits)
Share of the soil survey area's 337,268 acres, by the USDA rating “ENG – Septic Tank Absorption Fields”. Ratings assume a standard gravity trench system with no site changes, so “very limited” means a conventional field needs special design, not that septic is impossible.
What limits drain fields here
The most common limiting factors in Fremont County, Lander Area, as a share of all its land. One soil can have several, so the figures overlap.
Steep slopes57% of the county
Slopes over about 8% make it hard to keep trenches level and can let effluent seep out downhill.
Trenches are laid along the contour, often with serial distribution or drip dispersal.
Slow-draining subsoil46% of the county
Water moves too slowly through the soil 2 to 6 feet down, so effluent can back up or surface.
Designers usually answer with a larger drain field, shallower trenches, pressure dosing or a mound.
Shallow bedrock43% of the county
Rock lies within about 3 to 6 feet of the surface, so there is little soil to filter effluent before it reaches the rock.
At-grade systems, mounds or drip dispersal add soil depth above the rock.
Flood-prone ground5% of the county
The soil is on ground that floods, even if rarely, and a flooded drain field stops working.
Systems are placed above flood level, with watertight tanks and backflow protection.
High water table5% of the county
The water table rises to within 4 to 6 feet of the surface for part of the year, leaving too little dry soil to treat effluent.
Mounds, sand filters or treatment units that need less separation are common answers.
Main soils in Fremont County, Lander Area
The soils and land types covering the most ground. Search your address in the USDA Web Soil Survey to see which one is on your lot.
| Soil or land type | Share of county |
|---|---|
| Farlow | 10.5% |
| Sinkson | 7.5% |
| Forelle | 6.7% |
| Patent | 6.5% |
| Duncom | 5.0% |
| Blazon | 4.8% |
| Rock outcrop | 4.6% |
| Thermopolis | 3.9% |
Wyoming tank size rules
Homes with up to 4 bedrooms need 1,000 gallons. Add 150 gallons for each bedroom over 4.
| Bedrooms | Minimum tank |
|---|---|
| 1 BR | 1,000 gal |
| 2 BR | 1,000 gal |
| 3 BR | 1,000 gal |
| 4 BR | 1,000 gal |
| 5 BR | 1,150 gal |
| 6 BR | 1,300 gal |
Source: Wyo. Code R. 020.0011.25 Section 10(a).
Common questions
Can I put a conventional septic system in Fremont County, Lander Area?
Often, but not everywhere. The USDA rates 11% of rated land here as not or only somewhat limited for a standard drain field and 89% as very limited. Only a site evaluation on your lot can say which you have.
What size septic tank do I need in Fremont County, Lander Area?
Wyoming's minimum is 1,000 gal for 3 bedrooms and 1,000 gal for 4. Your county can require more.
What is the most common septic problem with soil in Fremont County, Lander Area?
Steep slopes, a limiting factor on about 57% of the county. Trenches are laid along the contour, often with serial distribution or drip dispersal.
More in Wyoming
Sources
- https://sdmdataaccess.sc.egov.usda.gov/
- https://websoilsurvey.nrcs.usda.gov/app/
- https://www.nrcs.usda.gov/resources/data-and-reports/soil-survey-interpretations
- https://www.epa.gov/septic/types-septic-systems
- https://www.law.cornell.edu/regulations/wyoming/020-25-Wyo-Code-R-SS-25-10
- https://pubs.nmsu.edu/_m/M113/