Sewage Ejector Pumps and Septic Systems
A basement bathroom below the outlet pipe needs an ejector pump to lift waste to the septic tank. Some states then require a bigger tank.
Minimum tank size
Choose your state and bedrooms, then press Calculate.
States that size the tank up for pumped flow
| State | Rule |
|---|---|
| New Jersey | Adds 50% and requires a multi-compartment tank |
| New Hampshire | Doubles the tank when raw sewage is pumped into it |
| North Carolina | Doubles the tank when a lift pump comes before it |
| Rhode Island | Adds 50% when more than a quarter of the flow is pumped |
Pumped flow arrives in surges that can stir settled solids toward the outlet, which is why these states want more volume. Elsewhere, ask your health department.
Plumbing code minimums
Most states use the International Plumbing Code for the pump and pit:
- Sump pit at least 18 inches across and 24 inches deep, with a gastight removable cover (IPC 712.3.2).
- Pumps that take toilet waste must pass 2-inch solids.
- Minimum capacity: 21 gpm for a 2-inch discharge, 30 gpm for 2½-inch and 46 gpm for 3-inch (IPC Table 712.4.2).
- A check valve and a full-open valve on the discharge line, and a vented pit.
Your state or city may amend these rules; Los Angeles, for example, uses the Uniform Plumbing Code instead.
A replacement pump costs $850–$3,800 installed; see ejector pump cost.
Common questions
Can an ejector pump go straight to the septic tank?
Yes. It discharges into the building drain or straight to the tank inlet. The tank then sees pumped surges, which is why some states require more volume.
Sources
- https://codelibrary.amlegal.com/codes/philadelphia/latest/philadelphia_pa/0-0-0-271023 (IPC 712.3.2 as adopted)
- https://codelibrary.amlegal.com/codes/newyorkcity/latest/NYCadmin/0-0-0-162807 (IPC Table 712.4.2 as adopted)
- https://www.homeadvisor.com/cost/plumbing/install-ejector-pump/
- https://dbs.lacity.gov/sites/default/files/efs/forms/pc17/2023-Sewage-Ejectors-Sump-Pumps.pdf
- https://trellis.law/state-rules/nj/administrative-code/title-7-environmental-protection/chapter-9a-standards-for-individual-subsurface-sewage-disposal-systems/subchapter-8-pretreatment-components/section-79a-82-septic-tanks
- https://regulations.justia.com/states/new-hampshire/env/subtitle-env-wq/chapter-env-wq-1000/part-env-wq-1010/section-env-wq-1010-01
- https://www.owpnc.com/18e-rules-nc/0801-septic-tank-capacity-requirements
- https://d1tvxue8o4w0fl.cloudfront.net/regulation/rhode-island-administrative-code/title-250-department-of-environmental-management/chapter-150-water-resources/subchapter-10-wastewater-and-storm-water/part-6-rules-establishing-minimum-standards-relating-to-location-design-construction-and-maintenance-of-onsite-wastewater-treatment-systems/section-250-ricr-150-10-627-septic-tanks