Minimum tank size
Virginia is selected. Choose your bedrooms and press Calculate.
Drain field suitability in Fairfax City
Soils in Fairfax City are mixed: 68% of rated land is very limited and 32% is not or only somewhat limited. The answer depends on the lot, so the soil test matters more than the county average.
- 0% not limited
- 21% somewhat limited
- 45% very limited
- 33% not rated (urban land, water, pits)
Share of the soil survey area's 3,421 acres, by the USDA rating “ENG – Septic Tank Absorption Fields”. Ratings assume a standard gravity trench system with no site changes, so “very limited” means a conventional field needs special design, not that septic is impossible.
What limits drain fields here
The most common limiting factors in Fairfax City, as a share of all its land. One soil can have several, so the figures overlap.
Slow-draining subsoil65% of the county
Water moves too slowly through the soil 2 to 6 feet down, so effluent can back up or surface.
Designers usually answer with a larger drain field, shallower trenches, pressure dosing or a mound.
Steep slopes14% of the county
Slopes over about 8% make it hard to keep trenches level and can let effluent seep out downhill.
Trenches are laid along the contour, often with serial distribution or drip dispersal.
High water table13% of the county
The water table rises to within 4 to 6 feet of the surface for part of the year, leaving too little dry soil to treat effluent.
Mounds, sand filters or treatment units that need less separation are common answers.
Drains too fast6% of the county
Coarse soil at the bottom of the trench passes effluent through before it is treated, which risks groundwater.
Pretreatment units or a sand liner slow the flow and finish the treatment.
Flood-prone ground5% of the county
The soil is on ground that floods, even if rarely, and a flooded drain field stops working.
Systems are placed above flood level, with watertight tanks and backflow protection.
Main soils in Fairfax City
The soils and land types covering the most ground. Search your address in the USDA Web Soil Survey to see which one is on your lot.
| Soil or land type | Share of county |
|---|---|
| Urban Land | 33.0% |
| Wheaton | 31.0% |
| Glenelg | 22.0% |
| Codorus | 4.4% |
| Hattontown | 2.7% |
| Orange | 1.5% |
| Sumerduck | 1.4% |
| Meadowville | 1.4% |
Virginia tank size rules
Homes with up to 2 bedrooms need 750 gallons, 3 bedrooms 900, 4 bedrooms 1,200 and 5 bedrooms 1,500. Larger homes are sized for 48 hours of design flow.
| Bedrooms | Minimum tank |
|---|---|
| 1 BR | 750 gal |
| 2 BR | 750 gal |
| 3 BR | 900 gal |
| 4 BR | 1,200 gal |
| 5 BR | 1,500 gal |
| 6 BR | Set locally |
Source: 12VAC5-610-815(A), Table 5.2.
Common questions
Can I put a conventional septic system in Fairfax City?
Often, but not everywhere. The USDA rates 32% of rated land here as not or only somewhat limited for a standard drain field and 68% as very limited. Only a site evaluation on your lot can say which you have.
What size septic tank do I need in Fairfax City?
Virginia's minimum is 900 gal for 3 bedrooms and 1,200 gal for 4. Your county can require more.
What is the most common septic problem with soil in Fairfax City?
Slow-draining subsoil, a limiting factor on about 65% of the county. Designers usually answer with a larger drain field, shallower trenches, pressure dosing or a mound.
More in Virginia
Sources
- https://sdmdataaccess.sc.egov.usda.gov/
- https://websoilsurvey.nrcs.usda.gov/app/
- https://www.nrcs.usda.gov/resources/data-and-reports/soil-survey-interpretations
- https://www.epa.gov/septic/types-septic-systems
- https://law.lis.virginia.gov/admincode/title12/agency5/chapter610/section815/
- https://pubs.nmsu.edu/_m/M113/