Home / By county / Washington
Septic Systems in Joint Base Lewis-McChord Area, Parts of Pierce and Thurston Counties, Washington
How much of Joint Base Lewis-McChord Area, Parts of Pierce and Thurston Counties the USDA rates as suitable for a septic drain field, what usually limits it, and the tank size Washington requires.
Minimum tank size
Washington is selected. Choose your bedrooms and press Calculate.
Drain field suitability in Joint Base Lewis-McChord Area, Parts of Pierce and Thurston Counties
Most rated land in Joint Base Lewis-McChord Area, Parts of Pierce and Thurston Counties is very limited for a standard drain field: 100% of it. Expect a site evaluation to point many lots toward a larger field, pressure distribution or an engineered system.
- 0% not limited
- 0% somewhat limited
- 87% very limited
- 13% not rated (urban land, water, pits)
Share of the soil survey area's 87,100 acres, by the USDA rating “ENG – Septic Tank Absorption Fields”. Ratings assume a standard gravity trench system with no site changes, so “very limited” means a conventional field needs special design, not that septic is impossible.
What limits drain fields here
The most common limiting factors in Joint Base Lewis-McChord Area, Parts of Pierce and Thurston Counties, as a share of all its land. One soil can have several, so the figures overlap.
Poor filtering layer79% of the county
Very permeable material 2 to 5 feet down filters effluent poorly.
Pretreatment or added fill gives the effluent more treatment before it reaches that layer.
Drains too fast74% of the county
Coarse soil at the bottom of the trench passes effluent through before it is treated, which risks groundwater.
Pretreatment units or a sand liner slow the flow and finish the treatment.
Large stones48% of the county
Stones over 3 inches make up a quarter or more of the top 16 inches, which makes trenches hard to dig and level.
Contractors may need heavier equipment or imported fill.
High water table18% of the county
The water table rises to within 4 to 6 feet of the surface for part of the year, leaving too little dry soil to treat effluent.
Mounds, sand filters or treatment units that need less separation are common answers.
Steep slopes17% of the county
Slopes over about 8% make it hard to keep trenches level and can let effluent seep out downhill.
Trenches are laid along the contour, often with serial distribution or drip dispersal.
Main soils in Joint Base Lewis-McChord Area, Parts of Pierce and Thurston Counties
The soils and land types covering the most ground. Search your address in the USDA Web Soil Survey to see which one is on your lot.
| Soil or land type | Share of county |
|---|---|
| Spanaway | 48.5% |
| Everett | 13.5% |
| Urban Land | 10.4% |
| McChord | 7.9% |
| Nisqually | 2.7% |
| Xerorthents | 2.2% |
| Semiahmoo | 1.7% |
| Spana | 1.7% |
Washington tank size rules
Homes with up to 4 bedrooms need 1,000 gallons. Add 250 gallons for each additional bedroom.
| Bedrooms | Minimum tank |
|---|---|
| 1 BR | 1,000 gal |
| 2 BR | 1,000 gal |
| 3 BR | 1,000 gal |
| 4 BR | 1,000 gal |
| 5 BR | 1,250 gal |
| 6 BR | 1,500 gal |
Source: WAC 246-272A-0232, Table VII.
Common questions
Can I put a conventional septic system in Joint Base Lewis-McChord Area, Parts of Pierce and Thurston Counties?
Often, but not everywhere. The USDA rates 0% of rated land here as not or only somewhat limited for a standard drain field and 100% as very limited. Only a site evaluation on your lot can say which you have.
What size septic tank do I need in Joint Base Lewis-McChord Area, Parts of Pierce and Thurston Counties?
Washington's minimum is 1,000 gal for 3 bedrooms and 1,000 gal for 4. Your county can require more.
What is the most common septic problem with soil in Joint Base Lewis-McChord Area, Parts of Pierce and Thurston Counties?
Poor filtering layer, a limiting factor on about 79% of the county. Pretreatment or added fill gives the effluent more treatment before it reaches that layer.
More in Washington
Sources
- https://sdmdataaccess.sc.egov.usda.gov/
- https://websoilsurvey.nrcs.usda.gov/app/
- https://www.nrcs.usda.gov/resources/data-and-reports/soil-survey-interpretations
- https://www.epa.gov/septic/types-septic-systems
- https://lawfilesext.leg.wa.gov/Law/WAC/WAC%20246%20%20TITLE/WAC%20246%20-272A%20CHAPTER/WAC%20246%20-272A-0232.htm
- https://pubs.nmsu.edu/_m/M113/