Estimated cost
Choose your state and bedrooms, then press Calculate.
Pumping interval by tank and household
| Tank | 1 person | 2 | 3 | 4 | 5 |
|---|---|---|---|---|---|
| 750 gal | 9 yr | 4 yr | 3 yr | 2 yr | 1 yr |
| 1,000 gal | 12 yr | 6 yr | 4 yr | 3 yr | 2 yr |
| 1,250 gal | 16 yr | 8 yr | 5 yr | 3 yr | 3 yr |
| 1,500 gal | 19 yr | 9 yr | 6 yr | 4 yr | 3 yr |
Years between pumpings for year-round occupancy, from New Mexico State University Guide M-113.
The EPA's general guidance is every 3 to 5 years, with an inspection at least every 3 years. A garbage disposal adds solids, so pump more often if you use one.
When the tank is due
An inspector measures the scum and sludge. The EPA says to pump when:
- The bottom of the scum layer is within 6 inches of the outlet.
- The top of the sludge layer is within 12 inches of the outlet.
- Scum and sludge together fill more than 25% of the liquid depth.
Common questions
Can I wait longer if the tank looks fine?
Only if an inspection says so. The EPA's test is the depth of sludge and scum, not how the system seems to work; solids that reach the field clog it for good.
Does a bigger tank need less pumping?
Yes. A 1,500-gallon tank serving four people needs pumping about every 4 years, against 3 years for 1,000 gallons, in New Mexico State University's table.