Minimum tank size
Virginia is selected. Choose your bedrooms and press Calculate.
Drain field suitability in New Kent County
Most rated land in New Kent County is very limited for a standard drain field: 92% of it. Expect a site evaluation to point many lots toward a larger field, pressure distribution or an engineered system.
- 0% not limited
- 8% somewhat limited
- 86% very limited
- 6% not rated (urban land, water, pits)
Share of the soil survey area's 114,592 acres, by the USDA rating “ENG – Septic Tank Absorption Fields”. Ratings assume a standard gravity trench system with no site changes, so “very limited” means a conventional field needs special design, not that septic is impossible.
What limits drain fields here
The most common limiting factors in New Kent County, as a share of all its land. One soil can have several, so the figures overlap.
High water table84% of the county
The water table rises to within 4 to 6 feet of the surface for part of the year, leaving too little dry soil to treat effluent.
Mounds, sand filters or treatment units that need less separation are common answers.
Slow-draining subsoil70% of the county
Water moves too slowly through the soil 2 to 6 feet down, so effluent can back up or surface.
Designers usually answer with a larger drain field, shallower trenches, pressure dosing or a mound.
Drains too fast65% of the county
Coarse soil at the bottom of the trench passes effluent through before it is treated, which risks groundwater.
Pretreatment units or a sand liner slow the flow and finish the treatment.
Steep slopes35% of the county
Slopes over about 8% make it hard to keep trenches level and can let effluent seep out downhill.
Trenches are laid along the contour, often with serial distribution or drip dispersal.
Flood-prone ground17% of the county
The soil is on ground that floods, even if rarely, and a flooded drain field stops working.
Systems are placed above flood level, with watertight tanks and backflow protection.
Main soils in New Kent County
The soils and land types covering the most ground. Search your address in the USDA Web Soil Survey to see which one is on your lot.
| Soil or land type | Share of county |
|---|---|
| Nevarc | 18.5% |
| Remlik | 16.2% |
| Emporia | 8.7% |
| Kempsville | 7.1% |
| Water | 5.3% |
| Caroline | 4.7% |
| Johnston | 4.4% |
| Altavista | 3.5% |
Virginia tank size rules
Homes with up to 2 bedrooms need 750 gallons, 3 bedrooms 900, 4 bedrooms 1,200 and 5 bedrooms 1,500. Larger homes are sized for 48 hours of design flow.
| Bedrooms | Minimum tank |
|---|---|
| 1 BR | 750 gal |
| 2 BR | 750 gal |
| 3 BR | 900 gal |
| 4 BR | 1,200 gal |
| 5 BR | 1,500 gal |
| 6 BR | Set locally |
Source: 12VAC5-610-815(A), Table 5.2.
Common questions
Can I put a conventional septic system in New Kent County?
Often, but not everywhere. The USDA rates 8% of rated land here as not or only somewhat limited for a standard drain field and 92% as very limited. Only a site evaluation on your lot can say which you have.
What size septic tank do I need in New Kent County?
Virginia's minimum is 900 gal for 3 bedrooms and 1,200 gal for 4. Your county can require more.
What is the most common septic problem with soil in New Kent County?
High water table, a limiting factor on about 84% of the county. Mounds, sand filters or treatment units that need less separation are common answers.
More in Virginia
Sources