Minimum tank size
Virginia is selected. Choose your bedrooms and press Calculate.
Drain field suitability in Northampton County
Most rated land in Northampton County is very limited for a standard drain field: 100% of it. Expect a site evaluation to point many lots toward a larger field, pressure distribution or an engineered system.
- 0% not limited
- 0% somewhat limited
- 59% very limited
- 41% not rated (urban land, water, pits)
Share of the soil survey area's 213,303 acres, by the USDA rating “ENG – Septic Tank Absorption Fields”. Ratings assume a standard gravity trench system with no site changes, so “very limited” means a conventional field needs special design, not that septic is impossible.
What limits drain fields here
The most common limiting factors in Northampton County, as a share of all its land. One soil can have several, so the figures overlap.
Drains too fast59% of the county
Coarse soil at the bottom of the trench passes effluent through before it is treated, which risks groundwater.
Pretreatment units or a sand liner slow the flow and finish the treatment.
High water table57% of the county
The water table rises to within 4 to 6 feet of the surface for part of the year, leaving too little dry soil to treat effluent.
Mounds, sand filters or treatment units that need less separation are common answers.
Slow-draining subsoil23% of the county
Water moves too slowly through the soil 2 to 6 feet down, so effluent can back up or surface.
Designers usually answer with a larger drain field, shallower trenches, pressure dosing or a mound.
Flood-prone ground21% of the county
The soil is on ground that floods, even if rarely, and a flooded drain field stops working.
Systems are placed above flood level, with watertight tanks and backflow protection.
Poor filtering layer7% of the county
Very permeable material 2 to 5 feet down filters effluent poorly.
Pretreatment or added fill gives the effluent more treatment before it reaches that layer.
Main soils in Northampton County
The soils and land types covering the most ground. Search your address in the USDA Web Soil Survey to see which one is on your lot.
| Soil or land type | Share of county |
|---|---|
| Water | 41.1% |
| Bojac | 22.4% |
| Chincoteague | 14.9% |
| Munden | 5.6% |
| Nimmo | 5.0% |
| Molena | 1.7% |
| Fisherman | 1.0% |
| Magotha | 0.6% |
Virginia tank size rules
Homes with up to 2 bedrooms need 750 gallons, 3 bedrooms 900, 4 bedrooms 1,200 and 5 bedrooms 1,500. Larger homes are sized for 48 hours of design flow.
| Bedrooms | Minimum tank |
|---|---|
| 1 BR | 750 gal |
| 2 BR | 750 gal |
| 3 BR | 900 gal |
| 4 BR | 1,200 gal |
| 5 BR | 1,500 gal |
| 6 BR | Set locally |
Source: 12VAC5-610-815(A), Table 5.2.
Common questions
Can I put a conventional septic system in Northampton County?
Often, but not everywhere. The USDA rates 0% of rated land here as not or only somewhat limited for a standard drain field and 100% as very limited. Only a site evaluation on your lot can say which you have.
What size septic tank do I need in Northampton County?
Virginia's minimum is 900 gal for 3 bedrooms and 1,200 gal for 4. Your county can require more.
What is the most common septic problem with soil in Northampton County?
Drains too fast, a limiting factor on about 59% of the county. Pretreatment units or a sand liner slow the flow and finish the treatment.
More in Virginia
Sources
- https://sdmdataaccess.sc.egov.usda.gov/
- https://websoilsurvey.nrcs.usda.gov/app/
- https://www.nrcs.usda.gov/resources/data-and-reports/soil-survey-interpretations
- https://www.epa.gov/septic/types-septic-systems
- https://law.lis.virginia.gov/admincode/title12/agency5/chapter610/section815/
- https://pubs.nmsu.edu/_m/M113/